02.04.2012

The leading manufacturer of sound masking & paging systems and complete acoustical solutions

Standard Speaker

Model BP2


Standard Speaker

When a networked direct-fired speaker or system is required, the Lencore CrossNetOne™ system provides the highest level of sound quality and adjustability and offers the ability for network control. Through the system’s managing software, zones can be created and modified for masking and paging. On-going changes and additions to zones can all be handled through the network interface without the need to rewire the system.

Multiple random sound masking sources, coupled with Lencore’s E-Sound™ technology provide capabilities for:

  • Masking Adjustments: 96 in ½ dB steps
  • Contour Adjustments: 29 steps

Installation is simplified using plug and play Cat 5e cable with standard RJ12 connections. The CrossNetOne™ speaker is equipped with dog ear screw adjustments and a locator pin to insure a smooth installation in ceiling tile or gypsum board.



















More Information

Speaker Enclosure:
Speaker Body: ABS Plastic
Grill: Metal screen, white with perforated 3.5” grill
Overall diameter - 4.5”

Speaker Coverage: 100 sq. ft. (assuming a 10’ speaker separation)

Loudspeaker:
2-inch wide dispersion
Power Rating: 3 watts
Frequency Response: 250 Hz to 20 kHz
SPL for Masking Output: 30-78dBA
Impedance: 32 Ohms
Resonant Frequency in Enclosure: 247 Hz
Resonant Frequency out of Enclosure: 250 Hz ± 20%
Weight: 112g (4 oz)
Cone: Paper Cone w/Foam Edge

General Specifications:
Paging Input: via BP-Net
Power Requirement: Powered by BP-Net
Output Adjustment: N/A

Speaker Wire Requirements:
All wire must be plenum rated and UL listed.
Speakers use Cat 5e, 3 twisted pair and RJ12 connectors.
Crossover wire: Pin 1 to Pin 6, Pin 2 to Pin 5, etc.

Other System Wire Requirements:
16 gauge, plenum rated, stranded, 2-conductor wire (for power supply to BP-Net).

System Power Supply: 48VDC, 150W for 192 speakers.

Installation:
Assembly to fit into a round hole, cut into ceiling tile or gypsum.
Three mounting locks spaced equidistant apart have secure screws for mounting.



The CrossNetOne™ Sound Masking System Performance Specification:

  • Direct-fired speaker.
  • All masking/paging units must be UL Listed for air handling space.
  • System must confirm following ANSI standards: ANSI S1.4, ANSI S1.6, and ANSI S1.11.
  • System must meet ASTM 1130-02, ASTM E1573-02, ASTM E 1374-93, and ASTM E 1041-85 standards.
  • The Sound Masking system must use a unique integrated sound masking, music and paging system that uses the power of network technology, web appliances, internet access, infrared remote controls and digital signal processors (DSPs).
  • The Sound Masking system must be capable of separately and independently configuring zones for sound masking, paging and music via the network empowered through its central control.
  • The Sound Masking system must produce 20Hz through 20,000Hz from its source.
  • The masking must be random and provide a minimum pattern of no LESS than 25 hours.
  • The sound masking devices must provide both a 1/3 octave band equalizer for a minimum of 30 bands and a parametric equalizer to adjust the sound masking.
  • The paging devices must have a minimum of a 1/1 octave band equalizer to shape sound.
  • The masking volume shall be adjustable via digital means for ½ dB steps for a range of 30-78 dBA as measured 1m from the center of the speaker
  • System must provide two sizes of speaker: 4 ½" and 8".
  • 4 ½" speaker housing must be produced from recycled ABS material. 8" speaker housings/enclosures must be damped to avoid undesirable resonance.
  • Sound masking system must be able to provide music muting capabilities to allow paging to smoothly override masking.
  • Spatial uniformity of sound must be no more than ±½ dBA.
  • Sound masking, paging and music must have individual identifiers located in an integrated LCD screen.
  • Plenum mounted network locations must have a lighted LED for visual inspection.
  • System must be a multi-drop network system. Point to point systems are unacceptable.
  • System must be capable of being tuned through a network and a hand-held remote.
  • The system must be capable of being independently zoned on both a global and local level for sound masking, paging and music. All zoning must be controlled from a network appliance.
  • Generation and integration of multiple random sound masking sources and by using E-sound® technology equates to the best sound and effective sound masking.
  • System must be capable of performing a complete diagnostics of its entire functions including diagnostics of the network, hubs, nodes, routers, DSPs, memory, circuitry, amplifiers and power.
  • System must be capable of reporting entire settings for each zone for masking, paging and music indicating at a minimum the volume, contour, 1/3rd band octave equalization, parametric equalization, diagnostics, and groupings.
  • System must be an open platform system. Proprietary software systems are UNACCEPTABLE.
  • System must be capable of using off the shelf browser software for full manipulation.
  • System must be capable of being used as a stand-alone system or a system tied into an intranet IT spine or manipulated through the internet.
  • System shall be designed so that individual speaker or component failure will have no impact on the balance of the system.
  • Security: Central control must only be able to be accessed via an authorized computer access point with the use of a password.
  • Sound masking equipment must be comprised of at least 50% recycled content.
  • A 10 year full warranty from the manufacturer must be provided. for all sound masking equipment.
  • The system must be manufactured in the USA.


 

All Lencore sound masking systems are custom designed to meet all local codes and to fit a variety of site conditions and applications in:

  • Open Plan
  • Closed Plan
  • Retrofit
  • New Construction


Applicable Environments

  • Commercial Office Interiors
  • Healthcare Facilities
  • Pharmacies
  • Financial Institutions
  • Doctors Offices
  • Banking Branch Offices
  • Call Center Environments
  • Government Facilities
  • Legal Institutions & Offices
  • Military Bases & SCIFS
  • Hotels
  • Library
  • Accounting Firms

Request a Quote



Use Lencore's Project Request Worksheet to request a quote.


CrossNetOne™
Sound Masking

MasterSpec

Download (Master Spec)


CrossNetOne™ Sound Masking Cut Sheets

Download (Cut Sheets)