02.04.2012

The leading manufacturer of sound masking & paging systems and complete acoustical solutions

Router

Model G70


Router

When a direct field speaker or system is required due to site conditions or application need, CrosswaysOne™ system provides the highest level of sound quality and adjustability.
CrosswaysOne™ offers a commercial grade direct field system using a higher quality construction and sound quality than competitive systems.

At approximately every 30th Platform, a Lencore CrosswaysOne™ router is typically used to ensure quality data transmission, page and music integrity among long Platform cable runs.

Connect a CAT 5e cable from the OUT data port of the 30th Platform to the data IN side of the router. Now connect another CAT 5e cable from OUT side of router to IN data port of 31st
Platform. Do similar connections after every 30th Platform in the system (see diagram on following page).

For CrosswaysOne™ Sound Masking System with page/music, connect internal jumpers to the screw terminals located on either end of the router to integrated Platform Amps after every
60th Platform in a run.

Page and music may also be routed out of the router via internal jumpers to the screw terminals located on either end of the router to integrated Platform amps or component amplifiers and equalizers for signal boost and correction. This setup is typically run at approximately the 60th Platform in a run.



More Information

NEVER PLUG A CrosswaysOne™ ROUTER INTO ANY COMPUTER OR NETWORK OR LIKE DEVICE OTHER THAN CrosswaysOne™ EQUIPMENT AS DAMAGE TO THE COMPUTER OR LIKE EQUIPMENT CAN OCCUR.

Router Input Voltage:
16-24 VAC or VDC

Power Input:
(Option 1) Screw Terminal: Use minimum 2 conductor 18 gauge plenum rated wire for power attachment.

Or

(Option 2) Power Brick Adapter: 5.5mm O.D 2.1mm I.D. – Center + Or Screw Terminal.

Inputs:
Data CAT 5e RJ45
Paging
Music
Audio Ground

Outputs:
Data CAT 5e RJ45
Paging
Music
Audio Ground

Size: 7 ½" x 4" x 2 ½"



The CrossWaysOne™ Sound Masking System must provide the following:

  • Direct field speaker.
  • All masking/paging units must be UL Listed for air handling space.
  • System must confirm following ANSI standards: ANSI S1.4, ANSI S1.6, and ANSI S1.11.
  • System must meet ASTM 1130-02, ASTM E1573-02, ASTM E 1374-93, and ASTM E 1041-85 standards.
  • The Sound Masking system must use a unique integrated sound masking, music and paging system that uses infrared remote controls.
  • Volume increments for paging and music MUST be in ½ dB steps never to exceed more than 1dB steps as measured 1m from the speaker.
  • The sound masking source must produce 20Hz through 20,000Hz.
  • The masking must be random.
  • The masking volume shall be adjustable via digital means for ½ dB steps for a range of 30-78 dBA as measured 1m from the center of the speaker.
  • Sound masking system must be able to provide muting capabilities.
  • Spatial uniformity of sound must be no more than ±½ dBA.
  • In open areas and larger enclosed spaces, the overall sound level produced should have spatial uniformity of no more than ±½ dB between any two sound generating units.
  • System must provide two sizes of speaker: 3 ½" and 6".
  • 3½" speaker housing must be produced from recycled ABS material. 6" speaker housings/enclosures must be damped to avoid undesirable resonance.
  • System shall be designed so that individual speaker or component failure will have no impact on the balance of the system.
  • Generation and integration of multiple random sound masking source and by using E-sound® technology equates to the best sound and effective sound masking.
  • Sound masking equipment must be comprised of at least 50% recycled Aluminum content.
  • A 10 year full warranty from the manufacturer must be provided for all sound masking equipment.
  • The system must be manufactured in the USA.


 

All Lencore sound masking systems are custom designed to meet all local codes and to fit a variety of site conditions and applications in:

  • Open Plan
  • Closed Plan
  • Retrofit
  • New Construction


Applicable Environments

  • Commercial Office Interiors
  • Healthcare Facilities
  • Pharmacies
  • Financial Institutions
  • Doctors Offices
  • Banking Branch Offices
  • Call Center Environments
  • Government Facilities
  • Legal Institutions & Offices
  • Military Bases & SCIFS
  • Hotels
  • Library
  • Accounting Firms